JUAL WAGO 750-319/004-000, Fieldbus Coupler LON®-Peer


Item no. 750-319/004-000
Description Fieldbus Coupler LON®-Peer
GTIN / EAN 4045454526801
Increase in order quantity (1, 2, 3, 4, ...) 
Customs Tariff no.   85176200000
Customs duty for the country of origin   DE
Manufacturer WAGO
Topology  acc. to LON specification 
Number of fieldbus nodes on the master max.  127 
Baud rate  0.078 Mbit/s 
Fieldbus segment length max.  2700 m; 500 m (free topology) 2700 m (bus-topology) 
Transmission medium  Twisted pair - FTT 
Number of modules per node max.  62 
Current consumption, system supply [mA]  300 mA 
Total current for system supply [mA]  1700 mA 
Field supply voltage  DC 24 V (-15 … 20 %); via power jumper contacts 
Input current typ. at rated load (24 V) [mA]  500 mA 
Efficiency of the power supply (typ.) at nominal load (24 V)  87 % 
Isolation  500 V system/supply 
Number of outgoing power jumper contacts 
Current carrying capacity of the power jumper contacts [A]  10 A
Connection technology: communication/fieldbus  LonWorks: 1 x 2-pole male connector 
Connection technology: field supply  6 x CAGE CLAMP® 
Connection technology: system supply  2 x CAGE CLAMP® 
Connection technology: device configuration  1 x 4-pole male connector 
Connection type (1)  System-/Feldversorgung 
Solid conductor  0.08 … 2.5 mm² / 28 … 14 AWG 
Fine-stranded conductor  0.08 … 2.5 mm² / 28 … 14 AWG 
Strip length  8 … 9 mm / 0.31 … 0.35 Inch 
Width  50.5 mm / 1.988 in 
Height  71.1 mm / 2.799 in 
Height from upper-edge of DIN-35 rail  63.9 mm / 2.516 in 
Depth  100 mm / 3.937 in 
Type of mounting  DIN-35 rail 
Color  light gray 
Housing material  Polycarbonate, polyamide 6.6 
Weight [g]  195.5 g
Conformity marking  CE 
Surrounding air (operating) temperature  0 … 55 °C 
Surrounding air (storage) temperature  -40 … 85 °C 
Degree of protection  IP20 
Degree of pollution (5)  2 per IEC 61131-2 
Operating altitude  0 … 2000 m 
Mounting position  horizontal (standing/lying) or vertical 
Relative air humidity (no condensation) [%]  95 %
Vibration resistance  acc. to IEC 60068-2-6 
Shock resistance  15g per IEC 60068-2-27 
EMC immunity to interference  acc. to EN 61000-6-2 
EMC emission of interference  acc. to EN 61000-6-4 
Exposure to pollutants  Per IEC 60068-2-42 and IEC 60068-2-43 
Permissible H2S contaminant concentration at a re  10 ppm
Permissible SO2 contaminant concentration at a re  25 ppm
Packaging type  BOX 
Product Family  750/753 Series I/O-System 
Main product function  Fieldbus couplers 
Product type  Fieldbus couplers 
[mm]  50.5 mm